Engine maintenance is needed to restore engine performance as expected.

Hubungi Kami
Studi Kasus
Service of Mechanical Cleaning — Water Jet on Air Cooled Heat Exchanger

Service of Mechanical Cleaning — Water Jet on Air Cooled Heat Exchanger

Pelanggan: CV. Cakrawala Persada for Exxon Mobil Cepu Limited

Ringkasan Spesifikasi

  • Air Cooled Heat Exchanger, Tag HFF681606
  • 3 Bay / 6 Bundle
  • Dimension: 11,520 L x 18,850 W x 4,400 H
  • Total Weight: 71,802 kg (Empty)

Yang Kami Kerjakan

  • Preparation work and secure working area
  • Prepare tools, equipment, safe working area, and waste management
  • Open 50% shoulder plug & plug gasket for 6 bundles, total 810 tubes (3 bay/6 bundle)
  • Prepare waste collection and management
  • Mechanical cleaning with water jet and heavy duty pump
  • Close shoulder plug & plug gasket
  • Perform leak test using nitrogen
  • Supply spare parts: Shoulder Plug (81 ea), Plug Gasket (810 ea)
Provision Of Cooler E-702, Exxon Bojonegoro

Provision Of Cooler E-702, Exxon Bojonegoro

Pelanggan: Exxon Mobile Cepu

Ringkasan Spesifikasi

  • 1 Unit Air Cooler Heat Exchanger
  • Dimension: 2,790 L x 9,800 W x 3,500 H
  • Total Weight: 69,300 kg (Empty)

Yang Kami Kerjakan

  • Install scaffolding on header side (right & left) for man-way and working access in open yard area
  • Open shoulder plug on header
  • Prepare tools, equipment, and collect waste (liquid waste containing HC and B3 only — treatment excluded from scope)
  • Mechanical cleaning water jet on inner tube with flexible lances: Fin Tube Qty 303 ea, Header x L 5,000mm x H 300mm x W 150mm x Qty 2 ea
  • Use heavy high pressure pump, back wash nozzle or rotary nozzle
  • Close plug & maintain tube plug hole if broken
  • Provide spare shoulder plug & gasket if broken
  • Perform nitrogen purging for leak test
  • Uninstall scaffolding